Anti-cant digital level ensures that your rifle is perfectly aligned, eliminating horizontal drift of your shots.
To monitor the alignment, look at the color of the LED.
- Blue color indicates deviation to the right.
- Red color indicates deviation to the left.
- Green color means that the rifle is aligned.
Level can be used in vertical and horizontal orientations, or even at an angle.
Out of the box the device is calibrated for horizontal position. To change this, position the device in the desired position and perform calibration.
Press — quickly release — press and hold the SG Pulse button — the LEDs will flash purple and then light up green, indicating that the SG Pulse has memorized this position as the zero horizon level. Please don’t touch the rifle and make sure it’s perfectly stable during calibration. If it continues to flash purple after 5 seconds, it means that the rifle is not stable enough. The sensor is extremely sensitive and can be affected by wind or by vibrations traveling through the rifle.
If you think that indication doesn’t make sense, this probably means that your SG Pulse is in Stability mode instead of Level Mode. To switch the mode, press and hold the button for 1 second.
You can also monitor the angle in the Drills app and configure the green zone limits.
In the Drills app, tap on the SG Pulse when it’s connected and go to “Horizontal level limit”. You can change the amount of inclination acceptable for a green zone on the device.